• Welcome to M-driver, your trusted ac drive manufacturer!
  • Company Add

    Longgang District,Shenzhen,China
  • E-mail

    admin@m-driver.com
  • Tel:+86 755 89369291

    M980 IP66 High-ingress Protection Drives

    0.75KW-15KW

    M980 IP55 is a high-performance and multipurpose VFD. The IP66 protection rating provides the best protection experience for most hash outdoor applications.

    3-7 Working Days For Standard Series

    Availability: OEM/ODM, Minmum Order Request
    Warranty: 18 Months
    • Description

    High performance frequency inverter

    1AC 220~240V / 0.75~15KW

    3AC 220~240V / 0.75~200kW

    3AC 380~460V / 0.75~560KW

    V/f, Vector speed control (IMSVC) of asynchronous motor,Vector speed control (FMSVC) of synchronous motor。


    ItemSpecifications
    Basic FunctionsMotor Control ModeV/F control
    Vector speed control (IMSVC) of asynchronous motor
    Vector speed control (FMSVC) of synchronous motor
    Maximum FrequencyVector Control0~500Hz      V/F Control0~500Hz
    Carrier Frequency0.5kHz~16kHz; the carrier frequency will be automatically adjusted according to the load characteristics.
    Input Frequency ResolutionDigital Setting 0.1Hz
    Analog Setting 0.01V corresponding maximum frequency ×0.1%
    Control ModeOpen Loop Vector Control(SVC), V/F Control
    Startup Torque0.5Hz/150%(SVC)
    Basic FunctionsSpeed Range and Precision1100(SVC)±0.5%(SVC)
    Overload Capability150% rated current 60s,180% rated current 3s
    Torque Boost0.1%~30.0%
    V/F CurveLine TypeSquare Type
    Acc. / dec CurveStraight line or S curve acceleration and deceleration mode
    Acceleration and deceleration time range between 0.0 to 500.0s.
    DC BrakeDC Brake Frequency0.00Hz to maximum frequency. Brake time 0.0s to 36.0s
    Multi-speed RunningIt can realize at maximum of 4 segments speed running via the control terminal.
    Built-in PIDIt is easy to realize process-controlled closed loop control system.
    Over-voltage/current Stall ControlIt can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process.
    Motor Over-temperature ProtectionAcceptable motor temperature sensor input (PT100, PT1000)
    Timing ControlTiming control functionset time range 0.0~6500.0Min
    Bus SupportSupport Site BusModbus
    Protection FunctionIt can implement power-on motor short-circuit detection, output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection, which can be turned on or shielded as required.
    RunningRunning Command SourceOperation panel reference, control terminal reference, and communication reference
    Target Frequency SourceDigital reference, analog signal reference, multi-segment speed reference, PI control reference, and communication reference
    Control Signal Input Terminal5 digital input
    2 analog inputsupport 0~10V4~20mA0~20mA20~0mA20~4mA and 10~0V signal
    Control Signal Output Terminal1 relay output, 2 analog input.
    2 analog outputsupport 0~10V4~20mA0~20mA20~0mA20~4mA and 10~0V 0~20mA signal
    EnvironmentUsing PlaceIndoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
    Altitude0~4000mDerating use when more than 1000m (decrease by 1% per 100 meters)
    Ambient Temperature-10  to +40  (Derating use when under ambient temperature of 40  to 50 )
    HumidityLess than 95%RH, without condensing
    VibrationLess than 5.9m/s (0.6g)
    Storge Temperature20~60
    IP LevelIP20
    Pollution LevelPD2
    Power Distribution SystemTN, TT

    General type three-phase 380V terminal wiring diagram:

    image.png